IPC707 signal conditioner

Signal conditioner for use with accelerometers (CA) and dynamic pressure sensors (CP).

The IPC707 signal conditioner is a high-quality, high-reliability charge-converter for use with piezoelectric sensors: CA accelerometers and CP dynamic pressure sensors.

The IPC707 is highly configurable (transfer function with optional integration, transfer sensitivity, high-pass and low-pass filtering, and optional diagnostic circuitry), and provides either a current output or a voltage output. It is compatible with different piezoelectric materials and replaces the previous versions of the IPC704 signal conditioner (PNR 244-704-000-xxx).

The IPC707 is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres). It is also designed for use in safety-related applications (functional safety contexts/systems) such as SIL2 in accordance with IEC61508 and PLcCat1 in accordance with ISO13849-1.Top of Form

GSI127 galvanic separation unit

Galvanic separation unit for use with vibration sensor (CA, CE, PV and VE), dynamic pressure sensor (CP) or proximity sensor (TQ) measurement chains.

The GSI127 galvanic separation unit is a high-quality, high-reliability unit for use with the IPC704 signal conditioner (used by CA accelerometers and CP dynamic pressure sensors), current-output accelerometers such as the CE134, CE281 and CE311, constant-current voltage-output sensors such as the CE110I, PV102 and CE680Mx11, the IQS450 signal conditioner (used by TQ proximity sensors) or the VE210 velocity sensor.

The GSI127 has a configurable transfer function and provides a voltage output. It is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres).

IPC704 signal conditioner

Signal conditioner for use with accelerometers (CA) and dynamic pressure sensors (CP).

The IPC704 signal conditioner is a high-quality, high-reliability charge-converter for use with piezoelectric sensors: CA accelerometers and CP dynamic pressure sensors.

The IPC704 is highly configurable (transfer function with optional integration, input and output sensitivities, high-pass and low-pass filtering), and provides either a current output or a voltage output. It is available in two versions for sensors using different piezoelectric materials (that is, standard piezoelectric material or GaPO4piezoelectric material).

The IPC704 is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres).

Note:The IPC704 signal conditioner is being replaced by the IPC707 signal conditioner.